CONSTRUCTIONTECHNOLOGY第42卷第12期 DOI:10.7672/sgj82013120090 响水涧抽水蓄能电站机组轴线调整技术*
范贵隆,林亚东 (武誉水电第二总队第八支队,福建厦门361009) [摘要】抽水蓄能机组安装中机组轴线调整的质量直接影响机组运行的稳定性、效率和机组寿命。
响水润抽水蓄 能电站在机组安装中利用新仪器精确测量机组转动部分各组数据,通过严密计算后进行机组轴线调整,实现了机 组轴线调整质量优良的目标。
[关键词]抽水蓄能电站;轴线;调整 [中图分类号]TV743【文献标识码]A[文章编号]1002-8498(2013)12-0090-03 AxisAdjustmentTechnologyofGeneratingSetin XiangshuijianPumped StoragePower Station Fan Guilong,Lin Yadong (No.8Detachment,No.2Hydropower Force ofArmed Police,Xiamen,Fujian 361009,China) Abstract:The quality of axis adjustment of generating set directly influences stability,effciency and life of thegenerating set running.During installation of generating set in XiangshuijanPumpedStoragePower Station, rotating part's data is measured by some new apparatuses, then these data are calculated to adjust the axis to gain good installation quality. Key words:pumped-storage power stations;axis;adjustment 响水润抽水蓄能电站位于安徽省芜湖市境内,轴的几何中心线与机组中心线偏差控制在一定范 为日调节纯抽水蓄能电站,装机容量为1000MW围内,将大大增加机组运行的稳定性。
(4x250MW),机组转速250r/min,轴线距离上导瓦 15.4m,转子质量438t。
机组为国内首台首套自主转子 研制、开发、设计、制造、安装、调试的可逆式抽水蓄主轴/定子 能机组。
机组转动部分由转轮、水轮机主轴、发电 机主轴、转子及上端轴5部分组成,部件间法兰连接下导瓦 处多,轴线长,调整难度大。
镜板 1机组轴线介绍推力头联轴法兰 机组轴线是指机组旋转大轴的几何中心线,如水导瓦 图1所示。
机组中心线是指套于水轮机和发电机转 动部分外面的主要固定部件的中心连线。
机组旋转轮 转中心线是指贯穿推力轴承镜板镜面中心的垂线。
图1机组轴线剖面示意 理论上“三条线”各自铅直且重合是机组的最佳状Fig.1 Unit axis profile 态,此时不存在摆度影响,但由于受到部件加工精 度、安装精度、推力瓦调整控制等因素影响,实际情2安装技术及方法 况不可能三线各自铅直且重合。
但如果在安装过2.1安装准备 程中通过提高标准、精度,改进工艺,使机组旋转大1)转动部分设备安装全部完成。
2)上机架吊人机坑,上盖板预装、下导内挡油 *武科研2012-62[作者筒介]范贵隆,工程师,E-mail:fgl13353666968@126.筒安装、油盆煤油试验完成,人力盘车工具安装、就 [收稿日期]2013-02-26位完成。
3)盘车前松开水导瓦,调整机组轴线中心,对 万方数据
2013 No.12范贵隆等:响水润抽水蓄能电站机组轴线调整技术91 称抱紧4块下导瓦。
行调整,直到满足要求。
4)集电环、上导轴承、下导轴承、镜板、主轴联6)调整推力瓦受力时应确保机组镜板面水平 轴法兰及水导轴承处分别在x,y方向布置百分表。
度控制在1mm以内。
5)在上导轴承处编号,编号时以+y方向为起推力瓦抗重螺栓压缩量:o,=o,-0o 始1号点,逆时针等距计数,共标识8个点,为盘车推力瓦抗重螺栓压缩量平均值: 时转动部位测量点,以便监测人员在盘车时报告测=(oo+20+0+,)/12(1) 量点数据。
推力瓦立柱调整值: 6)轴线调整所需的工(器)具准备、检查完成。
0=0+(0-0,)(2) 2.2转轮高程调整值确定式中:o为转轮高程调整值;o,为抗重螺栓压缩 1)转轮高程调整值由转轮进水口边与座环出值;o。
为抗重螺栓初始值;a,为...