Windows and doors -Air permeability-Testmethod

National foreword

This British Standard is the UK implementation of EN 1026:2016.It supersedes BS EN 1026:2000 which is withdrawn.

Committee B/538/1 Windows and doors. The UK participation in its preparation was entrusted to Technical

A list of organizations represented on this mittee can beobtained on request to its secretary.

provisions of a contract. Users are responsible for its correct This publication does not purport to include allthe necessaryapplication.

Published by BSI Standards Limited 2016 The British Standards Institution 2016.

ISBN 978 0 580 82209 4

ICS 91.060.50

Compliance with a British Standard cannot confer immunity fromlegal obligations.

This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 June 2016.

Amendments/corrigenda issued since publication

Date

Text affected

Supersedes EN 1026:2000

English Version

Windows and doors -Air permeability -Test method

Fenetres et portes - Permeabilite a I'air - Methoded’essai

Fenster und Turen - Luftdurchlassigkeit - Prufverfahren

This European Standard was approved by CEN on 9 January 2016.

CEN members are bound to ply with the EN/CENELEC Intemal Regulations which stipulate the conditions for giving this EuropeanStandard the status of aational standad without any alteration.Up-todate lists and bibliographical referencesconcerning such nationa standards may be obtained on aplication to the CEN-CENELEC Management Centre or to any CENmember.

translation under the responsibity of a CEN member into its own language and notifed to the CEN-CENELEC ManagementCentre has the same status as the official versions.

CEN members are the national standards bodies of Austria Belgium Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland Former Yugoslav Republic of Macedonia France Germany Greece Hungary Iceland Ireland taly Latvia Lithuania Luxembur Mata Ntlands way oland Portugal Rmia vaka Slovenia ain wede itland Tk d United Kingdom.

EUROPEAN COMMITEE FOR STANDARDIZATIONEUROPAISCHES KOMITEE FOR NORMUNG COMITE EUROPEEN DE NORMALISATION

CEN-CENELEC Management Centre: Avenue Marnix 17 B-10o0 Brussels

Contents

1 Scope. .52 Normative references. 53 Terms and definitions. .54 Principle of test... ..65 "snesedde s .66 Preparation of test specimen.... ..77.1 7 Test procedure. Preliminaries.. 7 77.2 Air permeability of test chamber .. 77.2.1 7.2.2 General... Test chamber with known air permeability.. 7 77.2.3 Overallair permeability of test specimen and the test chamber - positive pressures.....8 Test chamber withunknown air permeability7.3.1 7.3 General....7.3.2 7.3.3 Measurement of air permeability for windows and external pedestrian doorsets... Measurement of air permeability for internal pedestrian doorsets...7.48 Test result.9 Test report... ..9Annex A (informative) Test pressure sequences. 16Bibliography.. 17

Europeanforeword

windows shutters building hardware and curtain walling" the secretariat of which is held by AFNOR.

identical text or by endorsement at the latest by September 2016 and conflicting national standards shall be withdrawn at the latest by September 2016.

patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patentrights.

This document supersedes EN 1026:2000.

The revision of this European Standard clarifies the test method and does not affect existing testevidence of EN 1026:2000.

In parison with EN 1026:2000 the following significant changes were made:

a) Clause 2: Deletion of "Normative references";b) Clause 3: Supplement of definition “closing condition";c) Sub-clause 3.2: Simplification of definition “test pressure*;d) Sub-clause 3.4 and 3.5: Revision of definition opening joint";e) Sub-clause 5.4: Revision of definition accuracy*;f) Sub-clause 7.3: Addition of closing condition;g)Sub-clause 7.3: Separate test methods for measurement of air permeability for windows andexternal pedestrian doorsets in 7.3.2 and for internal pedestrian doorsets in 7.3.3;h) Clause 9: Supplement of necessary description of test specimen;i) Clause 9: Revision of Figures 1 and 2;j)Clause 9: Supplement of figures:- Figure 3 - Sliding door test specimen;- Figure 4 - Single leaf test specimen with fixed glazing;- Figure 5 - Single leaf test specimen with fixed glazing extension profiles and shutter boxes;

- Figure 6 - External / internal pedestrian doorset;

k) Revision of Annex A: Separation of figures into Figures A.1 and A.2.

following countries are bound to implement this European Standard: Austria Belgium Bulgaria According to the CEN/CENELEC Internal Regulations the national standards organizations of the