2015年5月上施工技术 第44卷第9期CONSTRUCTION TECHNOLOGY DOI:10. 7672/sgjs2015090033
毛细管网空调末端系统与装饰粉刷层组合饰面施工技术
杨晓华 (浙江宝业建设集团有限公司,浙江绍兴312028)
[摘要]毛细管网空调末端系统将Φ4.3mm×0.8mm塑料毛细管网敷设到室内顶板、墙面的粉刷层内,通过冷、热 水系统的循环,调节室内空气温度。
管网安装采取试压及保压措施,控制管网的渗漏。
石膏粉刷采取涂刮界面剂、 分层抹灰、铺设玻纤网格布及控制毛细管间距等措施,防止粉剧层开裂、空鼓及脱落。
经过实践应用,系统运行良 好,满足设计及使用功能要求。
[关键词】装饰装修;空调末端系统;毛细管网;石膏粉刷层;组合饰面;施工技术 [中图分类号]TU767.7[文献标识码]A[文章编号]1002-8498(2015)09-0033-04 ConstructionTechnologyofOvercoatingComposedofCapillaryNetwork Air-conditionTerminalSystemandPaintingLayer YangXiaohua (Zhejiang Baoye Construction Group Co.,Ld.,Shaoxing,Zhejiang 312028,China) Abstract:Capillary network air-condition terminal system buries plastic capillary network of 4. 3 multiply by 0.8 millimeters in the painting layer of indoor floors and walls.The indoor temperature can be adjusted through the circulation system between hot and cold water.Pressure test and pressure maintaining measures are adopted during installing the plastic capillary network to prevent leakage. Painting adhesion agent, layered plastering, laying fiberglass mesh and keeping distance among the plastic capillary network are used to keep painting layer away from cracking, hollowing and dropping. Practical application shows that this system runs well, and meets the design and functional requirement. Key words:decoration;air-condition terminal system;capillary network;plaster painting layer; bined overcoating; construction 0引言1技术特点 目前,高污染、高能耗对环境的影响已经越来1)节能毛细管网空调末端系统与常规风机 越为人们所重视,作为建筑产品高能耗的空调采暖盘管空调系统相比较,传热方式不同,所需的冷热 系统,其末端装置已从最原始的散热器开发出风机源供回水温度相差10℃,且热传导均匀,可节省能 盘管、地板辐射采暖等系统,但仍然存在着能耗大、源30%以上。
占用空间多、噪声大等缺点。
在综合分析各种空调2)使用安全可靠毛细管网水系统安装有过 技术指标、经济效益的基础上,创新性引进德国滤器,水质洁净,水压试压需保压至装饰结束。
加 CLINA毛细管网空调末端系统,并成功解决了毛细胶石膏和易性好、黏结性能强,网格布防开裂,可有
统既能采暖又能制冷,它应用人体毛细管的原理,3)能效比高,舒适性强与传统散热器和风机 将塑料毛细管网敷设到顶板、墙面的粉刷层内,通盘管系统比较,毛细管网空调系统从建筑物内墙 过冷、热水系统的循环,将能量均匀辐射到房间的面、天棚散热,热交换面积大、温度均匀、能效比高, 各个方位,调节室内空气温度。
且无风系统流动带来的温差、干燥与灰尘,舒适、洁 净、安静。
[作者简介]杨晓华,高级工程师,E-mail:627989442@q.4)施工技术易于掌握,操作便捷塑料毛细管 [收稿日期]2015-02-10网来取粘贴固...