施工技术 2015年5月上 20 CONSTRUCTIONTECHNOLOGY 第44卷第9期 DOI:10. 7672/sgjs2015090020 副框式单元玻璃幕墙设计与性能试验研究*
赵艳敏 (北京京北职业技术学院建筑工程系,北京101400) [摘要】为解决超高层建筑中副框式单元玻璃幕墙的构造设计问题,结合某实际工程介绍了其节点构造设计方案, 提出了计算排水透气孔面积的经验公式,解决了等压腔设计的关键问题,从而保证了副框单元式玻璃幕墙的水密 性能1nn另外,设计中将副框与主受力构件的组合截面作为计算截面进行变形计算1nn为验证设计方案的可行性,采 用1:1比例单元板块试验模型对其进行了气密性、水密性、风荷载位移变形性能及安全性能试验1nn最后结合设计与 试验结果分析,给出了超高层建筑中副框式单元玻璃幕墙相关设计建议1nn [关键词]装饰装修;高层建筑;副框式单元玻璃幕墙;设计;性能;试验 [中图分类号】TU767.6 [文献标识码】A [文章编号]1002-8498(2015)09-0020-04 DesignandPerformanceExperimentalStudyonUnitized GlassCurtainWallwithSub-frame ZhaoYanmin (DepartmentofConstructionEngineering,Northern BeijingVocationalEducationInstitute,Bejing101400,China) Abstract:To solve the structural design for the unitized glass curtain wall with sub-frame applied at super high-rise building,a project design scheme is introduced and the empirical formula for area of the drainage and air ventilation hole is proposed to solve the key issue of the pressure equalization cavity design which ensures the water tightness performance of the curtain wall. In addition,the pound section of main structural element and sub-frame is used for the deflection calculation in the design. The air permeability,water tightness,resistance to wind load,vertical and inter-story drifts and safety test with scale 1: 1 of the units model are developed for the design feasibility and the test results are studied. In the end,the design suggestions are proposed for the unitized glass curtain wall with sub-frame specified used for super high-rise buildings based on that. Key words:decoration; tall buildings; unitized glass curtain wall with sub-frame; design; performance; testing
0引言 副框式单元玻璃幕墙的构造设计方案决定了 副框式单元玻璃幕墙是采用结构胶黏结铝合幕墙的各项性能指标,对于建筑物的安全性、舒适 金副框和玻璃面板,在工厂用螺钉把横梁、立柱与性及外观的装饰美观性能等都具有重要影响1nn因 装的单元玻璃幕墙1nn安装完毕后的幕墙需要进行框式单元玻璃幕墙的设计提供参考依据,具有重要 拆换时可只更换工厂加工好的副框玻璃面板,无须 的理论和现实意义1nn本文对某超高层办公楼建筑 现场注结构胶,具有工业化程度高、现场安装速度副框式单元玻璃幕墙标准部位设计方案进行探讨, 快、工期短、拆卸方便、质量性能稳定等优点,该体 对其1:1单元板块模型试验结果进行分析研究,并 系也便于建筑进行后期的再节能改造,近年来在国 在此基础...
副框式单元玻璃幕墙设计与性能试验研究.pdf