2016年6月下施工技术 第45卷第12期CONSTRUCTIONTECHNOLOCY47 DOI:10.7672/sgjs2016120047
浮动地台在广州周大福金融中心施工过程中的应用
孙晖,晏瑾 (中国建筑第四工程局有限公司,广东广州510000) [摘要]通过浮动地台将整体设备基础和结构楼板进行隔离,采用柔性连接的方式降低设备对于邻近楼板的振动 冲击。
该工艺的施工可选用多种隔振材料及做法,浮动地台将整体设备基础和结构楼板进行硬性隔离,进而采用 柔性连接的方式,大大降低设备运行过程中对相邻结构楼层楼板的振动冲击。
较为详尽地介绍了浮动地台在广州 周大福金融中心中的运用。
[关键词]高层建筑;浮动地台;隔振胶垫;隔声量;施工技术 [中图分类号】TU974[文献标识码]A[文章编号〕1002-8498(2016)12-0047-02 Application oftheFloatingPlatformin ChowTaiFookFinance Centerin Guangzhou Sun Hui,Yan Jin (China Construction Fourth Engineering Division Co.,Lad.,Guangzhou,Guagndong 51000o,China) Abstract;The equipment base and structure flor are isolated by the floating platform,the flexible has lots of vibrated materials and methods. The rigid vibration is applied in the equipment base and structure floor with floating platform,then a flexible connection is used to absorb the shock of the equipment.The application of floating platform in Chow Tai Fook Finance Centre in Guangzhou is described in detail in this paper. Key words:tall buildings;floating platform;vibration isolation pad; sound-insulation values;construction 1工程概况和振动的标准,隔声效率越高,则降低噪声传输的 位于广州市核心CBD珠江新城J2-1,J2-3地块有效性越高,具体浮动地台的声学性能要求如表1 的广州周大福金融中心总承包工程项目(简称广州所示。
东塔项目)是典型的钢框架-核心筒结构。
该项目建3浮动地台的材料规格及型号 筑总高度为530m,地上111层,地下5层,裙楼3.1阻尼隔振胶垫物理属性 高60m。
选用的CDM阻尼隔振垫由50mm×50mm× 该项目塔楼主体结构由内部核心筒、外框筒850mm混合式橡胶合成聚合物+软木填塞组成,其 根巨柱、连接巨柱的6个空间环桁架以及4个伸臂工作负荷范围为0.3~0.6MPa,动态刚度:800~ 桁架组成,根据广东东塔项目的机电设计,大型机1100N/mm,阻尼系数:0.08~0.1,端变率:≤3%, 电设备(风机、水泵、制冷机组、风柜等)安装在设备动态模量G为8.0N/mm²,固有频率≤13Hz,楼板结 层中(L23,L40,L56,L67,L79,L92及夹层),由于部构和阻尼隔振垫的频率相差50%,以防二者发生共 分与设备层相邻楼层布置为办公室、多功能厅、会振,隔振垫压缩率50%卸载后永久变形≤5%,极限 议室等,为满足建筑隔声设计规范中对振动及隔声抗压强度须>15MPa,屈服强度极限>0.45MPa,弹 的要求,需设计一种浮动地台降低噪声的传递。
性模量须>7MPa,其力学性能如图1所示。
图2为 2浮动地台的设计隔振胶垫示意。
根据建筑结构的楼层功能设计、确定控制噪声3.2围边胶垫物理属性
PEF3200围边胶垫厚度为10mm,主要隔断竖 [作者简介]孙晖,项目副总工程师,E-mail:@qq.向墙体和浮动地台的硬性连接。
其拉伸强度为 [收稿日期]2016-03-05
万方数据
48施工技术第45卷
表1浮动地台的声学性能要求 Table 1Acoustics performance requirement for floating platform 实验室隔声量STC实地隔声量FSTC (根据ASTM E90及ISO140-1)(根据ASTME...