目次
1总则(1) 2术语(2) 3基本规定(4) 4设计(5) 4.1浆液(5) 4.2参数与指标(5) 4.3设计与计算(6) 5施工(8) 5.1一般规定(8) 5.2施工设备机具......(8) 5.3钻孔(9) 5.4试喷(10) 5.5变喷施工(10) 6工程质量检查和验收(13) 6.1工程质量检查(13) 6.2工程验收.(14) 附录A变喷防渗墙推荐施工参数(16) 附录B变喷防渗墙水泥浆造浆记录(17) 附录C变喷防渗墙钻孔记录(18) 附录D变喷防渗墙施工记录(19) 附录E变喷防渗墙施工过程质量检验 用词说明(21) 引用标准名录(22) 附:条文说明(23)
Contents
General provisions(1) 2Terms 3Basicrequirements 4Design(5) 4.1Slurry(5) 4.2Parameters and indicators 4.3Design and calculation(6) 5Construction.(8) 5.1General requirements(8) 5.2Construction equipment and tools(8) 5.3(9) 5.4Test of jet grouting(10) 5.5Variably spraying construction ..(10) 6Construction quality control andacceptance of project .......(13) 6.1 Construction quality control(13) 6.2Acceptance of project ...(14) AppendixARemended construction parameters of variably spraying cut-off wall AppendixB Grouting materials records ofvariably spraying cut-off wall(17) Appendix CDrilling records of variably spraying cut-off wall(18) Appendix D Constructionrecords ofvariably spraying cut-off wall .....(19)
7
AppendixEConstruction quality controlofvariably spraying cut-off wall(20) Explanation of wording(21) List of quoted standards(22) Addition:Explanation ofprovisions(23)
1总则
1.0.1为规范变角速高压旋喷防渗墙的工程应用,做到工程安 全、质量可靠、技术先进、经济环保,制定本规程。
1.0.2本规程适用于工程建设中采用变角速高压旋喷防渗墙的 设计、施工和质量检查与验收。
1.0.3变角速旋喷防渗墙的设计与施工应符合节约资源、保护 环境、绿色施工的原则。
应根据工程勘察成果资料、工程性质、 施工条件和场地环境条件,合理选择设计与施工参数,加强施工 过程中的信息化管理与质量控制。
1.0.4变角速高压旋喷防渗墙的设计、施工和质量验收除应符 合本规程规定外,尚应符合国家现行有关标准和现行中国工程建 设标准化协会有关标准的规定。
2术语
2.0.1高压旋喷防渗墙high-pressurejet groutingcut-offwall 高压旋喷管在360°水平范围内匀速旋转喷射并提升,形成 的圆柱形凝结体相互搭接组成的连续防渗墙体。
2.0.2变角速旋喷variably sprayingjetgrouting 通过控制旋喷嘴在360°水平范围内做变角速度旋转喷射并 提升,形成矩形等断面凝结体的高压喷射工艺,简称变喷。
2.0.3变角速高压旋喷防渗墙variablysprayingjetgrouting cut-off wall 采用变喷工艺形成的矩形断面凝结体互相搭接组成的连续防 渗墙体,简称变喷防渗墙。
2.0.4变角速度比ratioofvariable angularvelocity 旋喷管在360°范围内做变角速喷时采用的最大角速度与最 小角速度之比。
2.0.5单管法jet grouting with single pipe 喷射管为单一管路,喷射介质为水泥浆液的高压旋喷施工 方法。
2.0.6两管法jet grouting with double pipes 旋喷管为两管结构,同轴喷射高压水泥浆液和压缩空气的施...