Fixedfirefightingsystems-Watermistsystems
Part 16:Test protocol for industrial oil cookers for open nozzle systems
bsi.
Nationalforeword
This British Standard is the UK implementation of EN 14972-16:2019.
The UK participation in its preparation was entrusted to Technical Committee FSH/18/5 Watermist systems.
A list of organizations represented on this mittee can be obtained onrequest to its secretary.
This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.
The British Standards Institution 2019 Published by BSI Standards Limited 2019
ISBN 978 0 580 51114 1
ICS 13.220.20
legal obligations. Compliance with a British Standard cannot confer immunity from
This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 September 2019.
Amendments/corrigenda issued since publication
Date
Text affected
EN14972-16
English Version
Fixed firefighting systems-Watermist systems-Part 16: Testprotocolforindustrialoilcookersfor opennozzle systems
Installations fixes de lutte contre I'incendie - Systemes a brouillard d’eau - Partie 16 : Protocole d’essai dessystemes a buses ouvertes pour friteuses industrielles
Loschanlagen - Teil 16: Brandversuchsprotolcoll fur Ortsfeste Brandbekampfungsanlagen - Feinsprih-industrielle GroBfrittieranlagen fur Feinsprih- Loschanlagen mit offenen Disen
This European Standard was approved by CEN on 7 July 2019.
s u8 a suouo a ends p suena euau a/ ap m du o punqae siaqu n European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical referencesconcerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English French German). A version in any other language made bytranslation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria Belgium Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland France Germany Greece Hungary Ieland Ireland Italy Latvia Lithuania Luxembourg Malta Netherlands Norway Poland Portugal Republic of North Macedonia Romania Serbia Slovakia Slovenia Spain Sweden Switzerland Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATIONEUROPA1SCHES KOMITEE FOR NORMUNG COMITE EUROPEEN DE NORMALISATION
CEN-CENELEC Management Centre: Rue de la Science 23 B-1040 Brussels
Contents
1 Scope. 52 Normative references. 53 Terms definitions and abbreviations .54 Generalrequirements.5 Test equipment requirements .66 Industrial oil cooker mock-ups requirement .. .77 Instrumentationrequirements. .118 Testing Criteria. 119 Fire Tests. Test report.... 1210 .. 14
European foreword
firefighting systems" the secretariat of which is held by BSI.
identical text or by endorsement at the latest by February 2020 and conflicting national standards shall be withdrawn at the latest by February 2020.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
EN 14972 Fixed firefighting systems-Water mist systems consists of the following parts:
-Part 1:Design installation inspection and maintenance;--Part 2: Test protocol for shopping areas for automatic nozzle systems 1:-Part 3:Test protocol for office school classrooms and hotel for automatic nozzlesystems 1-Part 4: Test protocol for non-storage occupanciesfor automatic nozzle systems 1:--Part5 Test protocol for car garages for automatic nozze systems 1;Part 6:Test protocolforfalse floorsand falsecellingsforautomatic nozziesystems1--Part 7:Test protocol for mercial low hazard occupancies for automatic nozzle systems 1;-Part 8:Test protocol for machinery in enclosures exceeding 260 m3for open nozzie systems 1:-Part 9:Test protocol formachinery in enclosures not exceeding 260m3foropen nozzle systems 1;-Part10:Test protocolforatriumprotectionwith sidwallnozzlesforopenozzlesystems:--Part 11: Test protocol for cable tunnels for open nozzle systems 1:-Part 12:Test protocolformercialdeepfatcooking fryersforopennozzle systems1:-Part 13: Test protocol for wet benches and other similar processing equipment for open nozzlesystems 1;-Part 14: Test protocol for bustion turbines in enclosures exceeding 260 m3 for open nozzlesystems 1;Part 15: Test protocol for bustion turbines in enclosures not exceeding 260 m3 for open nozzlesystems 1;