沈加斌王耀南雷波李艳翟越 主要审查人:马建勋陈宁金伟良梁建国由世岐 谷倩张超
目
1总则(1) 2术语和符号(2) 2.1术语(2) 2.2符号(2) 3基本规定(4) 3.1检测条件(4) 3.2检测程序及工作内容(4) 4检测仪器(6) 5现场检测(8) 5.1抽样方法、检测单元和测点(8) 5.2检测方法(9) 5.3砌体墙现场检测(12) 6抗渗性能评定(13) 6.1墙体抗渗指标(13) 6.2数据分析与处理(13) 6.3评定方法(14) 6.4评定报告(15) 附录A抗渗性能系数等级评价法(16) 附录B墙体抗渗性能检测报告模板及检测记录表(17) 用词说明(20) 引用标准名录(21) 附:条文说明(23)
Contents
1General provisions(1) 2 Terms and symbols(2) 2.1 Terms(2) 2.2 Symbols(2) 3Basic requirements(4) 3.1 Testing conditions(4) 3.2Testing procedures and work contents(4) Testing instruments(6) 5Field testing(8) 5.1Sampling method,testing unit and testing point(8) 5.2Testing method(9) 5.3Field testing of masonry walls "(12) 6Assessment of impermeability(13) 6.1Impermeability index of wall(13) 6.2Data analysis and processing(13) 6.3Assessment method(14) 6.4Assessment report(15) Appendix A Impermeability coefficient grade evaluation method(16) Appendix B Test report template and test record sheet of wall impermeability(17) Explanation of wording(20) List of quoted standards(21) Addition: Explanation of provisions(23) 2
1 总则
1.0.1为规范砌体墙抗渗性能现场检测与评定的技术要求,做到 安全适用、技术先进、经济合理,制定本标准。
1.0.2本标准适用于采用水淋法对新建、既有砌体墙抗渗性能的 现场检测与评定。
准规定外,尚应符合国家现行有关标准和现行中国工程建设标准 化协会有关标准的规定。
2术语和符号
2.1术语 2.1.1水淋法现场抗渗检测field impermeability testing by water drenching method 以水为介质,保持一定的压力或流量并辅以喷淋装置模拟墙 体在风、雨天气作用下进行墙体抗渗性能原位检测的方法。
2.1.2检测单元testing unit 按面积划分的、供检测用的建筑墙体防水单元。
2.1.3测点testing point 在单面墙体内,取得检测数据的检测点。
2.1.4红外查漏法leakage testing method of infrared 利用红外热成像原理对待检测部位进行热成像拍摄,并根据 表面温差,查找渗漏位置的方法。
2.1.5抗渗性能leak-resistant ability 墙体在水、风压共同作用下抵抗渗透的能力。
2.1.6渗透压力osmotic pressure 墙体最终发生渗透时喷嘴处的水压力值。
2.1.7渗水量water seepage amount 检测全过程通过检测仪器渗人墙体的水量。
2.1.8抗渗性能系数impermeability coefficient 表征受检墙体抗渗性能强弱的系数。
2.2符号 m评价指标个数; P渗透压力; 2...