2013年8月下施工技术 第42卷第16期CONSTRUCTIONTECHNOLOGY95 DOI:10. 7672/sgjs2013160095
某地下通道渗漏治理技术
任生元 (江苏鼎达建筑新技术有限公司,江苏常州213015)
[摘要】某地下通道连接处应预留变形缝实际按施工缝施工,导致地下通道连接处混凝土底板、墙板和顶板变形缝 案,突出了选材在治理渗漏水的重要性,并详细介绍了施工工艺和施工要点,总结本工程治理渗漏的设计和施工 经验。
[关键词]防水工程;地下通道;变形缝;注浆;渗漏 [中图分类号】TU746.3[文献标识码]A[文章编号]1002-8498(2013)16-0095-03 Leakage Treatment on a Underpass Project Ren Shengyuan (Jiangsu Dingda New Construction Technology Co.,Lid.,Changzhou,Jiangsu 213015,China) Abstract:The connection of a underpass was supposed to be a deformation joint,but it was actually constructed as a construction joint,which caused leakage of the floor,wall and roof at both sides of the joint.Reasons for the leakage were analyzed for this project.A design scheme as well as construction plan was adopted to treat the problem. The importance of material selection is highlighted. The construction process and key construction points are introduced. At last, the author summarizes the experience on leakage treatment design and construction. Key words:waterproofing;underpass; deformation joint;grouting;leakage 1工程概况通道连接处混凝土底板、墙板和顶板变形缝两侧均 万博国际广场地处常州市商业核心区延陵路有明显的渗漏水现象,其中底板和侧墙(靠近底板 西段,亚细亚影城、莱蒙都会等商业体环绕周边,南附近)渗漏严重(见图1)。
侧与京杭大运河等历史文化遗迹毗邻。
项目总用 地30110m²,总建筑面积约30万m²,由1幢30层 住宅楼、3幢35层住宅楼、1幢38层办公楼、6层裙 楼和4层地下室组成,集休闲、娱乐、购物、办公、居 住等功能于一体的新一代城市综合体,该工程于 2010年3月开工,2012年11月峻工。
常州BRT2号线(快速公交线)邮电路地下通图1渗漏现状 道工程,始建于2008年5月。
为满足城市交通的要Fig.1 Leakage situation 求,万博国际广场地下1层与邮电路BRT2号线地 下通道连通,连接处设变形缝。
该通道主体结构采2渗漏原因分析 用C30防水混凝土,抗渗等级P8,防水等级一级。
由于本工程地下通道已建和接建2部分分属土 接建的万博国际广场地下1层地下通道与BRT2号木工程的不同子行业,其管理、设计和施工的主体 线地下通道于2012年9月打通,打通时发现该地下不同,已建方未按相关规范要求设置变形缝,且对 预留的橡胶止水带没有采取有效的保护措施,接建 [作者简介]任生元,总工程师,国家一级注册建造师,E-mail:rsy151方也没有按相应规范要求的变形缝施工。
在实际 @163.施工时,接建混凝土结构内钢筋直接采用植筋工艺 [收稿日期】2012-12-11
与原混凝土结构锚固,再浇筑混凝土,连接处按施 万方数据
96施工技术第42卷 工缝处理,未按变形缝施工。
不锈钢盖板 原BRT2号线地下通道建成于2008年,接建的可卸式止水带 万博国际广场地下通道建成于2012年,两者间存在方钢管、聚硫密封胶
胶粘剂、聚合物水泥砂浆 一定的沉降差。
同时地下通道混凝土温降及自身固定用栓钉 收缩变形等导致接建的万博国际广场地下通道与 原BRT2号线连接的施工缝处出现了较大裂缝。
另 外地下通道邻近京杭大运河,地表及地下水丰富, 京杭大运河(常州段)常年设计水位2.7m,设计最注浆针头预...