BS 4062-2-1990 液压动力系统阀门.第2部分性能测定方法.pdf

circuit,flow,Pressure,Valves,国外及港澳台标准
文档页数:32
文档大小:2.86MB
文档格式:pdf
文档分类:国外及港澳台标准
上传会员:
上传日期:
最后更新:

ISO6403:1988 BS4062:Part2:1990

(Corrected and roprinted May 1080)UDC 621.646.2/.4 : 021.22 : 532.57.08 : 620.1

BritishStandard Valvesforhydraulicfluidpowersystems Part2.Methodsfordeterminingperformance

Distributeurs pour transmissions hydrauliquesPartie 2. Methodes de determination des caracteristiques de fonctionnement

Teil 2. Verfehren zur Bestimmung der Leistung Ventile fur fluidtechnische Systeme

BritishStandardsInstitution

Contents

3Transient charactaristics for oporation of Pagedirectional control valves - Relationship 164Transientcharacteristics foroperationof between displacement and tlmedirectional control valves Relationship between pressure and time 155 Test circuit for direct-acting non-return valves 166 Test circuit for leakage flow of direct- acting non-return valves 167 Test circuit for pilot-pressure-operated non-return valves 17taaA Buanp-nd 1ns6 8Test circuit for pressure-relief valves 18 1910 Test circuit for flow control velives (meter-in 2011 Test circuit for flow control valves and thrge-way bleed-off) 2112 Test circuit for flow control valves (blood-off) (meter-out) 2213 Test cireuit for flow-dividing valves 14 Graphical representation of pressure/flowchareoteristics of pilot-pressure-operated non-roturn valves 2415 Graphicai representation of pllot pressures pxpermittingffow from port B to portA 2416 Grephical representation of stoady-stato pressure/flow characteristics for pressure-17Grophicalrepresntation of transintrespone relief valves 2518Graphicarepresentationofstady-statflow of valve controlling pressure 26characteristics of aflow control valve 2719 Graphical representation of transjent response of flow control valves 28

National foreword 1Committees responsible Back cover

Method

1Soope and field of application 0Introduction2 References 3 Definitions5 Tost installation General requirements 4Symbols and units6 Generai test conditions8Test procedure fornon-return lcheck)valves 7 Test procedure for directional control valves10 Test procedure for fiow control valves 9 Test procedure for valves controlling pressure11Test procedure for flow-dividing valves 12 Test report 1013 Identification statement

Annexes

A Classes of meesurement accurecy8 Use for practical units

Tables

2 Symbols and units Limits of permissible verietion of meenOutput pressure congitions indlicated values of controlled parameters4 Permissible systematicerrors ofmsuring instruments as determined during calibration5 Practical units

Figures

1 Test clrcult for directional control valves2 Switching evelope for directional control

National foreword

Thisrovised Britih Standerd prepereduner thedirection of the MachineryndComponents Standerds Policy Committee conoes the testing of valves used inhyrauli fluid powerytem and uprde BS4062:1082 whichis withdrwn.

ThisPartfBS4062desribsmthodsfordeterminingthe perfomnoefvalveudersteedysteteanddynmicconcitions:theyare identicalwiththemethodsdescrilbedinISO6403:19B8HydraulicfluidpowerValvscontrolling publihed in twoPertsPert1of which decribesmethod for determning thepressure differential/ftow character istics of valves under steady-state conditions.

Threclsfmsurmntcorac andCariated withthtetreetednpenixhls ofmesurementaccuracyshouldbeareedbeteenmanufactureranuserThmethodsfmasurementuedfortestingexetionallyontests wheretheattinmentf highaccuracishld toutifythegretlynreedtim andost scouraysrequredClAmethdfmesurementwillecessitatelboratoryconditionsndmaybemlyedexpended

ItsIendedthatthstandard wlunltytestinmethodsandnable terfmanefdifferenttesf almore reedily pared.

This revised odition of ISO 6403: 1088 oorrects inecourecies in 9.3 of the first edition and also incorporates other Improvements.

Cros-referenes

Intermetional stendard ISO 1219 : 1976 BS 2917 : 1977 Specificatlon for graphlcal symbols used on dlagrams for fluld power Corresponding British Standard(identical) systems and ponentsISO 4411 : 1986 BS 4062 Valves for hydraulic fluid power systemsPart 1: 1982 Methods for determining pressure differential/flow characteristics (identical)IEC Publication 85 (1984) BS 2757 : 1986 Method for determining the thermal classification of electrical insulation (ldentical)

TechicalCmittehasreviewed theprovlslnsf59owhihrefereneismadeinthetextandhas decided thet they are acoepteble for use in conjunotion with this standard.

Additinal ifomtonFtpupos f this ritish Stadar thIdentificatn statmnt I clause13 shouldbread as follows:

Testfordetminingsteedystateanddynmicperfomncecofom to theappropriatemethodsescribd InBS 4062 : Part 2 : 1080.

Complianeo with a British Standard does not of itself confer immunity from legal obligetipns.

Hydraulicfluidpower-Valvescontrollingflow andpressure-Testmethods

0Introduction

In hydraulicfluidpowerystempowrtranmittdandsooue ue u unssad apun pnbi e uno oo cirouit.Hydraulic valvee may be used to control the direction pressure or flow rate of the working fiuid by adjusting or controlling their resistanoe to flow.

ISO 4411 In whlch methods for detemining the steady-statedifferentiolprosaure/fliow characteristics of hydrauli valves are specified forms part of the same series of International Stan-derds.

The test requrementsfor productionpurposesmay differ from those specified in this International Standard.

1Scope and field of application

hydraullc valves whlch are used for the control of flow or ThisInternationalStandardspecifes methods fortetingpreseure in a circuit in order to dotormine their otoedy-state end dynamic performance.

Requirements for t installtinsand proceduresmesuements and presentation of results are speclfled.Thls Inter-national Standard does not establish limits of performancebe agreed between the manufecturer and the user.

Accurecy ofmsurement isdividedinto threeclasses (A,Band C whichare explained inannex A.Guidance as to the ueannex B.

Proportional control valves are not dealt with in this Inter-national Standard. Electrohydraulic servovalves are dealt with in ISO 6404

2 References

3Definitions

ISO1219 Fluid power systemsand ponentsGraphicsymbols.

ISO4411 Hydralcfluidpower-VaeDetemintionof pressure differential/flow characteristics.

ISO5598Fluidpowersystems andponentVocabufary.

IECPublication5 Thmlvinandlasitfefectricaf Insutaton.

For the purposes of thisInternational Standard the definitionsgiven in 1SO 5598 together with the foliowing. apply.

3.1bleed-off:A circuit condition where there is control overtheinletflowtoponntbydivringpartof thatflowtoa reservoir or part of a cirouit having lower pressure.

3.2meter-ln:A clrcult conditlon where there ls control over the inlet flow to a ponont.

3.3meter-out:A circuit oondition where there ls controlover the outlet flow from a ponent.

3.4volumetric stiffness:The stiffnes ofagivenportionofa hydraullc clrcult whlch is determined by the value of thepartial differential clrcult.

ISO 6403 : 1988 (E)

4Symbols and units

4.1Thnits andsymols sed throughoutthis ntionalStandard aro ao chown in tablo 1.

Table 1 Symbols and units

Nominal diamoter Quantity Symbol D Dimenslon1} 8l unit2Forco of valve mControl element - F MLT2 L N mtIinear dlsplacement Control element- radVolume flow rate angular displacement 1-4e7 - m²/sIntemal diameter gy d L Wof pipe Pressure differential p Ap ML-1T-2 PaTime aunseeudMass denslty of fuld 0 ML~3 T kg/m² 8Kinematic viscosity Temperature L2T-1 m2/s(customary)modluA Isensrople bulk K ML-1T-2 PaVolumo p 12 m?

1)M = mass; L = length;; T = time; = temperature2)The preotical units which may be used for the prsentation of results are tabulated in annex B.

4.2The grphlcal symbols usednthefgures depicting tstcircuito aro in acoordanco with 1SO 1219.

5Tostinstallation- General requiroments

5.1 Test circuit

5.1.1 A test circuit similar to those shown in figure 1 and figures5to13ndsuitablforthtype ofvalvebengtestednaccordance with the relevant clauses in this Internationel Stan-dard shall be used.

NOTES

1Although figure 1nd figures 5 to 13Hlustrete bes circuits whlchofmnntoeptbletoninegatedtsticit wihembraces two ormore test conditions.

2The figures in this International Standard showing batlo test dirgainst dmage in the vnt f cmponant fallur it i mportant thattrfordttstsdder safeguarding both personnel and equipment.

5.1.2A fluid supply with a controllable flow which has ahighermeximum than the rated ffow of the valve belng tested shall be used.

5.1.3 A pressure control valve in the eupply line shall be Installed to protect the circult from excess pressure.

Further control valvesasnecessary shallbe inetalld toregulate the fiow or pressure asrequlred.In varlous parts oftho cirouit.

5.1.4Tho inaide diameters of pipe and fittings that interfaco withthtestalean whichinl presurtappingpoinshalt be conslstent with the dlameters of the ports.

5.1.5 Draln ports shall be connected to a reservoir.

5.2Pressure-and tomperature-sensing points

5.2.1 Location of preesuro tappings

(see annxA) rureeadingstaknfopdineyattherpontsother than those describedInthls su-subctau wlglve suficient ccuracyproviding that where appropriste ooetionismadeforpelosses

Pressure tappings shall be provided both upstream and downstream of thevalve belng tested and f requlred at otherpointe.

5.2.1.1 The Inlet pressure tapping polnt shall be

alnot less than 10d downstream of any perturbation-produclng element such as a valve or a bend and

b)not fess than 5df upstream of the test valve.

5.2.1.2The outlet preuro topping point shall b not lessthan 10d downstream ot the test valve.

5.2.1.3The moosurod dote for pipe losses shall be corrected using the method described in ISO 4411.

5.2.2Pressure tappingo

5.2.2.1 The tappings shall have dlameters equal to or lessthan 0 1d but not lees than 1 mm nor greator then 6 mm.

5.2.2.2 The internal pipe surface at the topping shell be deburred without the sharp edge of tho tapping hole boingremoved.

5.2.2.3 3Thelengthof the tapping hole shallbenotlesthantwice the diarmeter.

5.2.2.4 The bore of the pipe containing the tapping shall becleen and smooth.

5.2.2.5The instrument-connecting pipes shal have bores not lees than 3 mm.

资源链接请先登录(扫码可直接登录、免注册)
①本文档内容版权归属内容提供方。如果您对本资料有版权申诉,请及时联系我方进行处理(联系方式详见页脚)。
②由于网络或浏览器兼容性等问题导致下载失败,请加客服微信处理(详见下载弹窗提示),感谢理解。
③本资料由其他用户上传,本站不保证质量、数量等令人满意,若存在资料虚假不完整,请及时联系客服投诉处理。
④本站仅收取资料上传人设置的下载费中的一部分分成,用以平摊存储及运营成本。本站仅为用户提供资料分享平台,且会员之间资料免费共享(平台无费用分成),不提供其他经营性业务。
投稿会员:匿名用户
我的头像

您必须才能评论!

手机扫码、免注册、直接登录

 注意:QQ登录支持手机端浏览器一键登录及扫码登录
微信仅支持手机扫码一键登录

账号密码登录(仅适用于原老用户)