附录A剪力墙结构水平接缝连接节点构造 本规程用词说明(43) 引用标准名录(44) 附:条文说明(47)
Contents
1General provisions(1) 2Terms and symbols(2) 2.1 Terms(2) 2.2 Symbols(3) 3Basic requirements 4Materials andproducts(5) 5Architectural design(8) 6Basicrequirements for structural design.(10) 6. 1 General requirements ......(10) 6.2 Structural analysis 6.3 Slab and stair(12) 7Design for frame structure(15) 7.1 General requirements ....(15) 7.2 Bott-connected frame structure(18) 7.3Monolithic precast concrete frame structure(22) 8Design for shear wall structure .....(24) 8.1 General requirements....(24) 8.2 Structural analysis(25) 8.3Precast shear wall design(25) 8.4Connection design(27) 9Design for frame-shear wall structure ...(34) 10Manufacturing and transportation(35) Construction and acceptance ....(36) 11.1 Construction ...(36) 11.2 Acceptance(38) .8.
Appendix AHorizontal joints detailing for shear wall structure(39) Explanation ofwording in this specification(43) List of quoted standards(44) Addition:Explanation of provisions(47)
1总则
1.0.1为在装配式多层混凝土结构的设计、施工及验收中贯彻 执行国家的技术经济政策,做到安全适用、技术先进、经济合 理、保证质量,制定本规程。
1.0.2本规程适用于抗震设防烈度不超过8度的陆地及岛礁环 境工业与民用建筑装配式多层混凝土结构的设计、施工及验收。
1.0.3装配式多层混凝土结构的设计、施工及验收除应符合本 规程外,尚应符合国家现行有关标准的规定。
2术语和符号
2.1术语 2.1.1装配式多层混凝土结构multi-storyprecastconcrete structure 由预制混凝土构件通过可靠的连接方式装配而成的层数不大 于6层且房屋高度不超过24m的混凝土结构。
2.1.2装配式多层混凝土框架结构multi-storyprecast con- crete frame structure 全部或部分框架梁、柱采用预制混凝土构件的装配式多层混 凝土结构,简称框架结构。
2.1.3装配式多层混凝土剪力墙结构multi-storyprecast con- crete shear wall structure 全部或部分剪力墙采用预制混凝土剪力墙板的装配式多层混 凝土结构,简称剪力墙结构。
2.1.4装配式多层混凝土框架-剪力墙结构multi-storyprecast concrete frame-shear wall structure 全部或部分剪力墙、框架梁、框架柱采用预制混凝土构件的 装配式多层混凝土结构,简称框架-剪力墙结构。
2.1.5干式连接节点dryjoint 预制构件之间主要通过螺栓、焊接等实现传力的连接方式。
2.1.6湿式连接节点wetjoint 预制构件之间预留混凝土后浇段,钢筋在后浇段内连接或锚 固,通过在后浇段内浇筑混凝土形成整体的连接节点。
2...