INTERNATIONAL STANDARD
First edition2014-05-01
Metersforirrigationwater
Compteurs pour l'eau d’irrigation
COPYRIGHTPROTECTEDDOCUMENT
@ ISO 2014
Al rights reserved Uless otherwise specified no part of this publiation may be reproduced or utilized otherwise in any formor by any means electronic or mechanical including photocopying or posting on the internet or an intranet without prior written permission. Permission can be requested from either ISO at the address below or ISO's member body in the country ofthe requester.
ISO copyright officeCase postale 56 • CH-1211 Geneva 20 Tel. 41 22 749 01 11E-mail copyright@ Fax 41 22 749 09 47
Published in Switzerland
Contents
Page
Technical characteristics.5.1 5.2 General specifications Rated operating conditions. 6 75.4 Indicating device. Materials. 75.5 Reverse flow. 8 75.6 5.7 Sealing and security. Other devices. 8 6
Metrological requirements.6.1 6.2 Indicating error. Internal pressure. 6 66.3 Flow profile sensitivity classes. Pressure loss. 66.4 10
Performance tests 11
7.1 General conditions for the tests. 117.2 7.3 Static pressure test. Determination of errors. 12 127.4 7.5 Flow disturbance tests. Pressure loss test. 14 147.6 Reverse flow test. 17Endurance tests. 18
Foreword
bodies (ISO member bodies). The work of preparing International Standards is normally carried outthrough ISO technical mittees. Each member body interested in a subject for which a technical mittee has been established has the right to be represented on that mittee. InternationalISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of organizations governmental and non-governmental in liaison with ISo also take part in the work.electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance aredifferent types of ISo documents should be noted. This document was drafted in accordance with theeditorial rules of the ISO/IEC Directives Part 2 (see
Attention is drawn to the possibility that some of the elements of this document may be the subject ofpatent:rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/oron the ISo list of patent declarations received (see
Any trade name used in this document is information given for the convenience of users and does notconstitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformityassessment as well as information about ISO's adherence to the WTO principles in the Technical Barriersto Trade (TBT) see the following URL: Foreword - Supplementary information
forestry Submittee SC 18 Irrigation and drainage equipment and systems. The mittee responsible for this document is ISo/TC 23 Tractors and machinery for agriculture and
Metersforirrigationwater
1Scope
This International Standard applies to water meters intended for irrigation use (herein after referred toand certification procedures for water meters irrespective of the design technologies used to meter the actual volume of cold water or heated water flowing through a fully charged closed conduit. These watermeters incorporate devices which indicate the integrated volume.
and to water meters based on mechanical principles incorporating electronic devices used to meter the actual volume flow of cold water. It provides metrological requirements for electronic ancillarydevices when they are subject to metrological control. As a rule the ancillary devices are optional. However national or international regulations make some ancillary devices mandatory in relation tothe utilization of the water meter.
2 Normativereferences
The following documents in whole or in part are normatively referenced in this document and areindispensable for its application. For dated references only the edition cited applies. For undated references the latest edition of the referenced document (including any amendments) applies.
ISO 4064-1:2005 Measurement of water flow in fully charged closed conduits - Meters for cold potablewater and hot water - Part 1: Specifications
ISO 4064-2:2005 Measurement of water flow in fully charged closed conduits - Meters for cold potablewater and hot water -Part 2: Installation requirements
ISO 9644 Agricultural irrigation equipment - Pressure losses in irrigation valves - Test method
ISO 286-2 Geometrical product specifications (GPS) - ISO code system for tolerances on linear sizes - Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts
ISO 228-1 Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions tolerances and designation
ISO/IEC Guide 98-3 Uncertainty of measurement -Part 3: Guide to the expression of uncertainty inmeasurement (GUM:1995)
3 Terms and definitions
For the purposes of this document the following terms and definitions apply.
water meter
instrument intended to measure continuously store and display the volume of water passing through the measurement transducer at metering conditions
Note 1 to entry: A water meter includes at least a measurement transducer a calculator (including adjustment orcorrection devices if present) and an indicating device. These three devices may be in different housings.
[SOURCE: OIML R49-1:2006 2.1.1 modified - The second note is not included here.]